USING THE US EPA SURFACE
EMISSION ISOLATION FLUX CHAMBER TO ASSESS EMISSIONS FROM AN AREA SOURCE
INTRODUCTION
Assessing the emission rate of volatile organic compounds (VOCs) from
any an source presents a variety of challenges for environmental scientists.
Area sources include waste treatment and disposal facilities (landfills,
land farms, compost facilities, municipal wastewater treatment, industrial
solvent treatment), surface spills, industrial processes, and subsurface
contamination such as contaminants in groundwater (plume). Emission rate
data are preferred over concentration data (mass/volume) for most applications
because emissions rate data can be used for many purposes including: process
compliance, health risk assessment, and
designing emission control technologies. The most common
usage of emission rate data is to determine yearly emissions of VOCs (mass/year)
per emission source. Emission rate data are thus useful for assessing long-term
air quality impacts.
There are many acceptable approaches for assessing emissions from area
sources. The US EPA has published technical guidance manuals and formalized
the approach for conducting air pathway analysis (APA) at hazardous sites.
This effort is in support of site restoration activities including conducting
exposure assessments for undisturbed and disturbed (i.e., during remediation)
waste sites (EPA Volumes 1-4, 1989). Although written for assessing emissions
from uncontrolled hazardous waste sources (i.e., Superfund hazardous waste
landfills and lagoons), the technologies described are applicable to any
area or fugitive source. Volume II of this four volume guidance series
focuses on estimating emission rate from area sources such as hazardous
waste landfills and lagoons (EPA Volume 2, 1989). The emission assessment
approaches and their respective technologies described in Volume II describes:
direct emission measurement, indirect emission measurement, fenceline monitoring
and modeling, and predictive modeling. These three measurement approaches
for measuring or estimating emission rate as described in APA Volume II
and their respective assessment technologies, are paraphrased from Volume
II and are discussed below.
Several factors will determine which technology or combination of technologies
will be appropriate for evaluating a given site. And some sources are a
combination of sources (i.e., point and area sources or multiple area/fugitive
sources) and require several assessment technologies in order to generate
representative emission rate data. These factors include an a priori estimate
of compounds emitted and emission rate; the level of effort available to
determine these emission rates; the degree of accuracy required; and the
complexity of the source.
An important distinction to make in understanding the emission rate (mass/time)
measurement technologies is whether the technology directly measures the
emission flux (rate/area or mass/time, area) of a VOC at the source or
the effect of the emission event (i.e., ambient concentration of the VOC).
Technologies that directly measure the emission event must measure all
of those parameters that are necessary to calculate an emission rate. An
emission rate (mass/time) can be calculated by multiplying the emission
flux rate (mass/time,area) by the surface area responsible for the emission
event. Most technologies that measure the ambient concentration must use
an interpretation (such as dispersion modeling) to determine the associated
emission rate. Other methods calculate the pollutant concentration in a
manner where the emission is not directly related to a given area or time
interval. These technologies typically use air dispersion modeling to infer
the emission rate responsible for the emission concentration measured given
the unique source, dispersion, and transport conditions of the testing.
One last concept needs introduction prior to a discussion of assessment
technologies. This concept includes the definitions of emission assessment
approach or technologies, sample collection techniques, and analytical
methodologies. The emission assessment approach or
technology is the technical approach or scheme used to estimate
emissions which incorporates sample collection and the analysis of samples.
There are three emission measurement approaches and one modeling approach:
direct measurement, indirect measurement, air monitoring (or fenceline
monitoring) and dispersion modeling, and predictive emissions modeling.
These approaches, which are composed of several technologies within these
categories, are very different. Each type of technology has unique advantages
and disadvantages providing for one best approach or technology per application.
The three measurement techniques rely on assessing flux or the effect of
flux using a measured parameter. Predictive modeling relies on estimating
the release of VOCs from the source and the migration of the VOCs to the
land surface.
ASSESSMENT APPROACHES
Direct emission measurement approach is often the preferred
approach for assessing VOC emissions from waste treatment
processes and other area sources. This is because these technologies
are relatively easy to use, are source-specific which allows for the
assessment of single processes at sites with multiple VOC emission
sources (i.e., no upwind interferences), they are not significantly
influenced by meteorological conditions, and they do not require
modeling in order to estimate emissions.
Direct emission measurement of covered and vented processes is straight-forward
and the assessment is made by measuring gas velocity, vent cross-sectional
area, and concentration of VOCs in the vent gas. This approach is standard
vent or "stack sampling" technology and provides accurate and
reliable emission assessment. Direct emissions measurement for area sources
or fugitive (process vent leaks) sources consists of measuring the gas
concentration, flow rate, and surface emissions area for the emission event
at the emitting surface prior to dispersion into the atmosphere. Air is
typically purged into the enclosed chamber as a carrier gas or sweep air.
Technologies applicable to volatile emission rate measurements from surfaces
are the surface emissions isolation flux chamber, (Radian, 1989; Eklund
et al, 1985; Dupont, 1987; Eklund et al, 1987; Schmidt and Clark, 1983),
head space samplers (Kapling et al, 1986), and wind tunnels (Castle, 1982;
Cowherd, 1985). Cracks in surface covers also may be sampled by these technologies
(Schmidt, 1990). Vents at uncontrolled hazardous waste sites typically
have minimal or no flow and may be sampled by the above technologies or
by head space emissions concentration measurements (Wood and Porter, 1986).
Where measurable gas flow velocities are present, vent emission rates can
be sampled by standard stack sampling methods.
Surface Emission Isolation Flux Chamber
The surface emissions isolation flux chamber is one of the most promising
technologies for the direct measurement of VOC emissions. Guidelines have
been developed by the EPA for application of this methodology to land surface
(Radian, 1988). The technology is also applicable to liquid surfaces (Eklund
et al, 1985; Eklund et al, 1987). The technology uses a chamber to isolate
a known surface area for emissions measurement. Clean, dry sweep air is
added to the chamber at a metered rate. Within the chamber, the sweep air
is mixed with emitted vapors and gases by the physical design of the sweep
air inlet and/or an impeller. The concentration of the exhaust gas is measured
at the chamber outlet for specific VOCs by real-time instruments and/or
is usually collected as a sample for laboratory analysis. The emission
flux can be calculated as:
Ei = CiQ / A
where Ei = emission rate of component i (ug/m2,min); Ci =
concentration of component i (ug/m3); Q =
sweep air flow rate into chamber (m3/min); and A =
surface area enclosed by chamber (m2).
Statistical methods are used to determine the number of measurements required
to characterize the emissions from an area source. These methods are based
on the source surface area and the variability of the measured emission
rate at randomly selected locations across the site. The principal advantages
of this technology are that an emission rate can be measured in the field
without modeling, and the field personnel can control the testing conditions.
The area source measurement is made at the emitting surface, whether the
surface is a solid, a liquid, an opening (crack), or a vent. The principal
disadvantage is that the measurement is made over a relatively small area
and numerous measurements may be necessary to characterize an emission
source. Also, the emission flux may be enhanced or suppressed in the process
of performing the measurement thus altering the emission event.
The EPA recommended flux chamber technology as described in the literature
can be applied to a variety of area sources with only minor adaption and
equipment modification. The following sub-sections describe the applications
of the technology to land surfaces, non-aerated, non-mixed liquid surfaces,
aerated and mixed liquid surfaces, and fugitive process emission sources.
Land Surfaces. The flux chamber was designed
and tested for land surfaces where the volatile/semi-volatile source (waste
material) is on the surface or is subsurface. The difference regarding
surface versus subsurface applications is that for direct contact with
the waste, emission rates are generally greater and those rates are often
subject to influences such as solar heating, ambient temperature, surface
moisture, and physical disturbance of the waste material. Where the waste
material is subsurface and the volatile species must migrate through a
layer of soil, the emission rates can be lower and often are not affected
by surface conditions or activity.
Assessing VOC species emissions from surface waste sources such as landfills,
stock piled waste, and land farms is a straight-forward and common application
of the technology. Since the chamber will be in contact with the waste,
contamination of equipment and cross-contamination is a concern. This concern
can be addressed by cleaning the chamber walls where contact with waste
has been made and back-flushing the chamber exhaust or sample line. One
approach is to avoid contact by wrapping the chamber lip with wide, disposable
teflon tape per test location and preventing contact with solid waste material.
Care must be taken to not introduce materials into the chamber like adhesive
tape that may off-gas contaminate species. All wrapping must be secured
outside the chamber. In addition to cleaning and preventing limiting contact
with waste, more frequent (10-to-20%) blank testing is recommended for
testing with waste contact.
Non-Aerated, Non-Mixed Liquid Surfaces. Application
of the technology to liquid surfaces requires floating or suspending the
chamber on/over the liquid surface. For non-aerated and non-mixed liquid
surfaces such as abandoned lagoons and ponds, quality assurance testing
has demonstrated that lower emission rates will result if the chamber lip
significantly penetrates the liquid surface and prevents communication
of the isolated surface with the waste body (Gholson et al, 1988). In non-mixed
liquid systems, natural mixing occurs by heating and cooling of the surface
layer and the resulting connective mixing. If the chamber contains a layer
of trapped liquid, the volatile species may diffuse and the resulting liquid
layer may retard emissions. This could result in a bias in test data (in
this case, a negative bias). This bias can be prevented by suspending the
chamber and keeping the chamber lip floating just under the liquid surface.
Flotation/suspension systems have been designed and used successfully (Eklund
et al, 1987). Aside from this concern, liquid testing can be accomplished
following the testing protocol as described for land surfaces including
spatial and temporal test strategies.
Aerated, Mixed Liquid Surfaces. Aerated
and/or mixed surfaces, usually associated with a treatment process like
municipal sewage or industrial waste water treatment, are tested using
the flux chamber as per quiescent surfaces (Schmidt et al, 1991; Schmidt
and Faught, 1990). Mixed liquid surfaces usually prevent a low bias in
the emission estimate by continually renewing the liquid surface. For vigorous
mixing, it may be necessary to attach flotation devises to the chamber
to improve the stability of the equipment preventing chamber upset.
Aerated surfaces are unique in that bulk air flow from the system strips
volatile species and carries contaminants into the chamber. This air flow
must be measured and used in the calculation for determining emission rate.
Aeration flow can be measured by attaching a volume-calibrated, deflated
plastic bag to the chamber pressure port, sealing all other ports, and
timing the bag filling (Schmidt and Faught, 1990). Dividing bag volume
by filling rate affords the aeration flow rate assessment. Aeration rate
can also be measured using a pump and a manometer to match flow at zero
pressure difference and a mass flow measuring device such as a rotometer.
In assessing emissions from an aerated treatment process, both aerated
and non-aerated zones must be assessed independently. Average unit emission
rate from each zone and estimated surface areas are needed to assess emissions
from each zone. Soil biofilters with forced aeration, which are aerated
systems similar to aeration basins, have also been tested using this technology
(Berry et al, 1991).
Process Fugitive Seam/Leak Assessment. The
flux chamber technology can also be used to assess emissions from passive
vents, seams, leaking valves, ports, and cracks in control devices ranging
from fixed and floating roofs to clay caps on landfills (Schmidt and Clark,
1990). These applications require modifications to the standard protocol:
1) the chamber must be adapted to the fugitive source; and 2) the process
or source must be well understood in order to properly design a testing
strategy and assess the area source. Adapting the chamber to these fugitive
emission sources can be as simple as placing the chamber on a flat seam
or as involved as constructing an adaptor to interface between the port,
valve, or process opening. When possible, these adapters should be made
from inert materials and the entire system should be blank tested. Operating
conditions like flow rate and residence time parameters may need to be
changed due to increased enclosure volume.
The requirement of representative testing, however, is a bigger challenge
for this application. Typically, process seam/fugitive emissions are first
surveyed with real-time analyzers and all fugitive emissions are identified,
organized into zones or ranges of similar emission potential, and tested
as zones of emissions potential as described for land surfaces. An estimate
of emissions can be obtained by averaging emission rate per zone and calculating
emissions per zone by knowing the number of sources, area of source, or
lineal feet of source. Unit emission rate data for this type of source
can have units like mass per time per vent or foot of seam leak (Schmidt
and Clark, 1990).
DISCUSSION
When selecting an emission assessment approach, use of an accurate and
precise technology is desirable to allow the generation of representative
emission estimates. The selection of assessment approach, assessment technology,
and then sample collection technique and analytical methodology will depend
on many factors, most important of which include: type of emission source
(point or area source); type and level of VOCs emitted from the source;
other source characteristics such as heterogeneity and dynamic properties,
accessibility, surrounding interfering sources, and meteorological conditions;
and capabilities available to conduct the emission assessment like expertise,
equipment, and laboratory facilities.
When possible, direct emission measurement technologies, such as the emission
isolation flux chamber, should be used to measure emission rates from waste
bodies because they offer inherently greater sensitivity and lower variability.
As such, the flux chamber is the ideal tool for collecting accurate data
from low-level sources such as volatilization of compounds from contaminated
groundwater. This application provides data that is useful in providing
input to an exposure assessment when contaminated groundwater leaves the
site and impacts a neighboring community.
REFERENCES
Astle, A.D., Duffee, R.A., and Stankunas, A. R., 1982. Estimating Vapor
and Odor Emission Rates from Hazardous Waste Sites, Natl. Confer. on Managm.
of Uncontrl. Haz. Waste Sites, US EPA, Washington, D.C.
Balfour, W. D., Schmidt, C. E., and Eklund, B.M., Sampling Approaches
for the Measurement of Volatile Compounds at Hazardous Waste Sites, Radian
Corporation, Austin, Texas.
Balfour, W, D., Weatherold, R. G., and Lewis, D. L., 1984. Evaluation
of Air Emissions from Hazardous Waste Treatment, Storage, and Disposal
Facilities, EPA 600/2-85/057, 2 Vols., US EPA, Cincinnati, OH.
Batterman, S., McQuown, B., McFarland, A., 1991. A Passive Soil Gas Flux
Sampler: Laboratory and Field Evaluation, 89th Annu. Meet. of the Air and
Waste Man. Assoc., Vancouver, B.C.
Bath, R. J., et al, 1989. Remote Sensing of Air Toxics Using State-of-the-Art
Techniques, Proc. of the 1989 EPA/AWMA Symp. on Measu. of Toxic and Related
Air Pollu., Raleigh, NC.
Berry, R.S., C.E. Schmidt, R.C. Wells, 1991. An evaluation of sampling
strategies for determining soil filter control efficiencies. Presented
at the 1991 AWMA Symposium, 91-17.4, Vancouver, Canada.
Cowherd, C., 1985. Measurement of Particulate Emissions from Hazardous
Waste Disposal Sites, 78th Annual Meeting of the Air Pollu. Contr. Assoc.,
Detroit, MI.
DuPont, R.R., 1987. Measurement of Volatile Hazardous Organic Emissions, J.
Air Pollut. Control Assoc., 37(3), 168.
Eklund, B. M., Balfour, W. D., and Schmidt, C.E., 1985. Measurement of
Fugitive Volatile Organic Emission Rates., Environ.
Progr., 4(3), 199.
B.M. Eklund, M.R. Keinbusch, D. Ranum, and T. Harrison, "Development
of a Sampling Method for Measuring VOC Emissions from Surface Impoundments",
Radian Corporation, Austin, TX, no date. 7 pp.
Eklund, B.M., Keinbusch, M.R., Ranum, D., and Harrison, T., Development
of a Sampling Method for Measuring VOC Emissions from Surface Impoundments,
Radian Corporation, Austin, Texas.
G.J. Esplin, 1988. Boundary layer emissions monitoring. JAPCA Vol. 38,
No. 9, 1158-1161.
Farmer, W. J., Yang, M. S., Lety, J., and Spencer, W. F., 1980. Land Disposal
of Hexachlorobenzene Waste: Controlling Vapor Movement in Soil, EPA 600/280-119,
US EPA, Cincinnati, OH.
Lodge, J. P., 1989. Editor, "Methods of Air Sampling and Analysis," 3rd
Edition, Lewis Publisher, Inc., Chelsea MI.
A.R. Gholson, J.R. Albritton, K.M. Jayanty, J.E. Knoll, 1988. "Evaluation
of the Flux Chamber Method for Measuring Volatile Organic Emissions From
Surface Impoundments", Final Report for U.S. E.P.A. Contract
No. 68-02-4550.
Hudson, Judy, et al, 1991. Remote Sensing of Toxic Air Pollutants at a
High Risk Point
Source Using Long Path FTIR, 84th Air and Waste Management Association
Annual Meeting, Vancouver BC.
Hwang, S. T., 1982. Measuring Rates of Volatile Emissions from Non-Point
Source Hazardous Waste Facilities, 75th Annu, Meet. of the Air Pollu. Contr.
Assoc., New Oreleans, LA.
Hwang, S.T., 1985. Model Prediction of Volatile Emissions, Environ.
Progr., 4(2), 141.
Kapling, E.J., Kurtz, A. J., and Rahimi, M., 1986. VOC Sampling for Emission
Rate Determination and Ambient Air Quality on an Inactive Landfill, New
England Section, Air Pollution Control Association, Fall 1986 Conference,
Worcester, MA.
Kerfoot, H. B., 1987. Soil-Gas Measurement for Detection of Ground-Water
Contamination by Volatile Organic Compounds, Environ.
Sci. Technol., 21 (10), 1002.
McLaren, S. E., Stedman, D. H., 1990. Flux Measurements Using Simultaneous
Long Path Ultraviolet and Infrared Spectroscopy, 83rd Annu. Meet. of the
Air and Waste Man. Assoc., Pittsburgh, PA.
Radian Corporation, 1986. Measurement of Gaseous Emission Rates From Land
Surfaces Using an Emission Isolation Flux Chamber User's Guide, EPA Contract
No. 68-02-3889.
Radian Corporation, 1987. "Air Quality Engineering Manual for Hazardous
Waste Site Mitigation Activities", Revision 2. Air Quality Engineering
and Technology, Department of Environmental Quality CN027. Note: List of
compounds comes from a draft EPA communique.
Riggin, R. M., 1983. "Technical Assistance Document for Sampling
and Analysis of Toxic Organic Compounds in Ambient Air," EPA-600/4-83-027,
USEPA Research Triangle Park, NC.
Riggin, R. M., W. T. Winberry, 1986. "Compendium of Methods for the
Determination of Toxic Organic Compounds in Ambient Air (Supplement to
EPA-600/4-84-041," EPA-600/4-87-006, USEPA Research Triangle Park,
NC.
Schmidt, C. E., and Balfour, W. D., 1983. Direct Gas Emission Measurement
Techniques and the Utilization of Emissions Data from Hazardous Waste Sites,
Natl. Conf. Environm. Eng. Proc., Environ. Eng. Div. ASCE.
C.E. Schmidt, J. Clark, 1990. Use of the Surface Isolation Flux Chamber
to Assess Fugitive Emissions from a Fixed-Roof on an Oil-Water Separator
Facility. Presented at the 1990 EPA/AWMA Measurement of Air Toxics, Raleigh,
NC.
C.E. Schmidt, W.R. Faught, J. Nottoli, 1991. Using the EPA recommended
surface emission isolation flux chamber to assess emissions from aerated
and non-aerated liquid surfaces. Presented at the 1991 EPA/AWMA Measurement
of Air Toxics, Raleigh, NC.
C.E. Schmidt, and W.R. Faught, 1990. "Review
of Direct and Indirect Emission Measurement Technologies for Measuring
Fugitive Emissions From Waste Water Treatment Facilities",
American Institute of Chemical Engineers Symposium, San Diego, CA.
Schmidt, C. E., Vandervort, R., and Balfour, W.D., 1986. Technical Approach
and Sampling Techniques Used to Detect and Map Subsurface Hydrocarbon Contamination,
79th Annual Meet. Air Pollu. Contr. Assoc., Minneapolis, MN.
Scotto, R. L., Minnich, T. R., Leo, M. R., 1990. Emissions Estimation
and Dispersion Analysis Using Path-Integrated Air Measurement Data From
Hazardous Waste Sites, 83rd Annu. Meet. of the Air and Waste Man. Assoc.,
Pittsburgh, PA.
Spellicy, R. L., et al 1991. "Spectroscopic Remote Sensing: Addressing
Requirements of the Clean Air Act," 24, Spectroscopy,
6(9).
Thibodeaux, L. G., D.G. Parker, and M.M. Heck, 1982. Measurements of volatile
chemical emissions from wastewater basins. USEPA, Hazardous Waste Engineering
Research Laboratory, EPA 600/5-2-82/095, Cincinnati, Ohio.
U.S. Environmental Protection Agency, 1983. "Technical Assistance
Document for Sampling and Analysis of Toxic Organic Compounds in Ambient
Air," EPA-600/4-83-027, Environmental Monitoring Systems Laboratory,
Research Triangle Park, NC.
U.S. Environmental Protection Agency, 1989. Office of Air Quality Planning
and Standards, Air Superfund National Technical Guidance Study Series,
Volume 1, "Application of Air Pathway Analysis for Superfund Activities," Interim
Final, EPA-450/1-89/001.
U.S. Environmental Protection Agency, 1989. Office of Air Quality Planning
and Standards, Air Superfund National Technical Guidance Study Series,
Volume 2, "Estimation of Baseline Air Emissions at Superfund Sites," Interim
Final, EPA-450/1-89/002.
U.S. Environmental Protection Agency, 1989. Office of Air Quality Planning
and Standards, Air Superfund National Technical Guidance Study Series,
Volume 3: "Estimation of Air Emissions from Cleanup Activities at
Superfund Sites," Interim Final EPA-450/1-89/003, USEPA.
U.S. Environmental Protection Agency, 1989. Office of Air Quality Planning
and Standards, Air Superfund National Technical Guidance Study Series,
Volume 4: "Procedures for Dispersion Modeling for Superfund Air Pathway
Analysis," Interim Final EPA-450/1-89/004, USEPA.
U.S. Environmental Protection Agency, 1990. "Development of A Statement-of-Work
(SOW) for the Analysis of Air Toxics at Superfund Sites As Park of the
Contract Laboratory Program (CLP)," Proceedings of the 1990 EPA/AWMA
International Symposium on Measurement of Toxic and Related Air Pollutants.
Whitcraft, W. K., Wood, K. N., 1990. Use of Remote Sensing to Measure
Wastewater Treatment Plant Emissions, 83rd Annu. Meet. of the Air and Waste
Man. Assoc., Pittsburgh, PA.
Whitherspoon (EBMUD tracer)
Winberry, W. T., Norma Murphy, 1989. First and Second "Supplement
to Compendium of Methods for the Determination of Toxic Organic Compounds
in Ambient Air," U.S. Environmental Protection Agency, Environmental
Monitoring Systems, Research Triangle Park, NC, EPA-600/4-87-006 September
1986 and EPA-600/4-89-018.
Wisner, C.E., and Davis, T.W., 1989. Characterization of Fugitive Emission
Rates Using a Mobile Integrating Sampler, Proc. of the 1989 EPA/AWMA Symp.
on Measu. of Toxic and Related Air Pollu., Raleigh, NC.
Wood, J.A., and Porter, M.L., 1986. Hazardous Pollutants in Class II Landfills,
South Coast Air Quality Management District, El Monte, CA.
Return to top of page CE Schmidt, Ph.D
Environmental Consultant
19200 Live Oak Road, Red Bluff, California 96080
PHONE: (530) 529-4256 FAX: (530) 529-4878
Please call today, or send an email to SCHMIDTCE@aol.com
|
|